Laserfiche WebLink
• EXHIBIT B <br />CODE OF FEDERAL REGULATIONS SECTION 76.605 <br />§ 76.605 Technical Standards. <br />(a) As of six (6) months and ninety (90) days following publication in the <br />Federal. Register), unless otherwise noted, -the following requirements apply to the <br />performance of a Cable System as measured at any Subscriber terminal with a <br />matched impedance at the termination point or at the output of the modulating or <br />processing equipment (generally the headend) of the Cable System or otherwise as <br />noted. The requirements are applicable to each NTSC or similar video downstream <br />cable television Channel in the System: <br />(1) The cable television channels delivered to the Subscriber's terminal <br />shall be capable of being received and displayed by TV broadcast receivers used <br />for the off -the -air reception of TV broadcast signals, as authorized under Part 73 <br />of this chapter. <br />(2) The aural center frequency of the aural carrier must be 4.5 MHz t 5 <br />kHz above the frequency of the visual carrier at the output of the modulating or <br />processing equipment of a Cable System, and at the Subscriber terminal. <br />• (3) The visual signal level, acrossa terminating impedance which <br />correctly matches the internal impedance of the Cable System as viewed from <br />the Subscriber terminal, shall not be less than 1 millivolt across an internal <br />impedance of 75 ohms (0 dBmV). Additionally, as measured at the end of a 100 - <br />foot cable Drop that is connected to the Subscriber tap, if shall not be less than <br />1.41 millivolts across an internal impedance of 75 ohms (+3 dBmV). (At other <br />impedance values, the minimum visual signal level, as viewed from the <br />Subscriber terminal, shall be the square root of 0.0133(Z) millivolts and, as <br />measured at the end of a 100 -foot cable Drop that is connected to the Subscriber <br />tap, shall be two times the square root of 0.00662(Z) millivolts, where Z is the <br />appropriate impedance value.) <br />(4) The visual signals level on each Channel shall not vary more than 8 <br />decibels within any six-month internal which must include four tests performed in <br />six -hour increments during a 29 -hour period in July or August and a 24-hour <br />period in January or February, and shall be maintained within: <br />(i) 3 decibels (dB) of the visual signal level of any visual carrier <br />within a 6 MHz nominal frequency separation; <br />(ii) 10 dB of the visual signal level on any other Channel on a <br />Cable System of up to 300 MHz of cable distribution System upper <br />frequency limit, with a 1 dB increase for each additional 100 MHz of cable <br />• distribution System upper frequency limit (eg. 11 dB for a System at 301- <br />400 MHz; 12 dB for a System at 401-500 MHz, etc.); and <br />B-1 <br />