74 <br />G4NERAL ORDINANCES 293 <br />means of ingress or egress; except as an additional means of <br />,egress during a conflagration, flood, panic or other disaster; shall <br />be wholly and entirely inclosed within the walls of the building. <br />This does -not apply to entrances on the rear of buildings. <br />Sec. 494(28). Fire stops. <br />At each floor level in all buildings hereafter erected, all stud <br />walls, partitions, furring and spaces between joists where they <br />rest on division walls or partitions, shall be fire -stopped with in- <br />combustible material in a manner to completely cut off communi- <br />cation by fire through concealed spaces. Such fire -stopping shall <br />extend the full depth of the joists, and at least four (4) inches <br />above each floor level. Stair carriages shall be fire -stopped at <br />least once in the middle partition of each run. <br />Sec. 494(29). Areaways. <br />Areaways constructed under any street or alley shall not ex- <br />tend into the same more than 50 per cent of the width of the <br />adjacent sidewalk, and in no case shall they extend a distance <br />greater than three feet beyond the lot line. Areaways must be <br />covered with transparent sidewalk lights or metal gratings ca- <br />pable of sustaining a live load of not less than 200 pounds per <br />square foot, the open spaces between the bars or other members <br />shall not exceed 5/8 of an inch in width. In no case shall area- <br />ways be constructed as a means of ingress or egress from the <br />building, nor for the transmittal of goods or other articles to or <br />from the building, but shall be used only for the admission of <br />light and air. <br />No permit for the construction of areaways shall be allowed <br />until a written agreement, as prescribed by the council, between <br />the City and the owner of the property has been executed. This <br />agreement shall stipulate that the present owner, and any future <br />owner, of the property shall construct and maintain the area- <br />way in a safe and proper condition, and that said owners shall <br />be liable for all damages and injuries caused by the construc- <br />tion, maintenance or use of said areaways, and shall indemnify <br />and save harmless the City from all such damages and injuries. <br />It shall further stipulate that the areaways may be removed or <br />altered by the City at any time upon ten days' written notice to <br />294 CHARLOTTESVILLE CITY CODE <br />the owner. Said agreement shall be recorded in the Clerk's Of- <br />fice of the Corporation Court of this City at the expense of the <br />owner. <br />Sec. 494(30). Dwelling houses—prohibited location. <br />No dwelling house or sleeping quarters shall be placed over, <br />or be connected directly with a stable, barn, haymow, public <br />garage, dry cleaning establishment, planing mill, carpenter shop, <br />paint shop or filling station. <br />Sec. 494(31). Frame buildings—construction. <br />(a) No frame building hereafter erected or altered shall ex- <br />ceed two stories in height, except that private dwellings may <br />be three stories high. <br />(b) No frame building hereafter erected for any occupancy <br />other than grain elevators, coal elevators and pockets, ice houses, <br />exhibition buildings, and structures for temporary occupancy for <br />a specified period and then subject to special permission shall <br />cover a ground area exceeding the following: <br />One story building -7,500 sq. ft. <br />Two story building -5,000 sq. ft. <br />(c) In no case shall the extreme projection of a frame build- <br />ing be erected within 5 feet of the side or rear lot line, nor with- <br />in 10 feet of another building on the same lot, unless the space <br />between the studs on such side be filled solidly with not less <br />than 2/ inches of brick work or other equivalent incombustible <br />material, in which case said distances may be reduced to 3 feet. <br />(d) Rows of frame tenement houses are prohibited. Duplex or <br />double frame houses shall be permitted. In rows of tenements <br />constructed of brick or other similar material there shall be a <br />twelve inch fire wall between each two units. <br />(e) Buildings with wooden framework clad with sheet metal, <br />or veneered with brick, shall be classed as frame buildings. <br />(f) The maximum spacing for studding and joists shall be <br />sixteen inches on centers, that for rafters twenty-four inches. <br />Studding in external walls and all partitions of dwellings shall <br />be not less than standard two by fours (2 x 4) standing with <br />studs set the four inch way for thickness of walls. The ex- <br />terior of the framework of all dwellaugs shall be sheathed with <br />GENERAL ORDINANCES 295 <br />sheathing not less than three-fourths (Y4) inches thick. In case <br />of built-up beams or girders, the splicing of members shall be <br />made over supports. In case of house to be weatherboarded <br />sheathing may be omitted if framework is sufficiently braced <br />against wind pressure. <br />Where the frame is properly cross -braced, sheathing may be <br />eliminated and wood laths embedded in asphaltic binder directly <br />connected to heavy felt roofing material may be applied directly <br />to the studding when stuccoed according to provisions elsewhere <br />outlined in this section. Such lathing material shall meet the ap- <br />proval of the Building Inspector. Where wire or metal laths <br />are used on sheathing board there must be a furring strip %" <br />thick placed not more than 16 inches on centers. <br />(g) All floors of wood construction in dwellings shall be con- <br />structed of not less than two by eight (2 x 8) standard wood <br />joists. All joists and studding around openings such as doors <br />and windows shall be doubled. Openings more than four feet <br />wide in bearing partitions shall be trussed or framed over with <br />beams of ample size to carry the full load above. All headers <br />over four (4) feet in length that butt into trimmers shall be car- <br />ried on metal joist hangers or mortized and tenoned headers and <br />trimmers. There shall be at least one horizontal row of two by <br />four (2 x 4) pieces in each story to provide a fire stop closing off <br />the entire space between studding. <br />(h) The following schedule of joist sizes and spacings shall <br />be followed as a minimum for dwellings and tenements, assuming <br />a total load dead and live for 60 lbs. to a sq. ft. using seasoned <br />short leaf yellow pine lumber. <br />Maximum Span for Floor Joist <br />296 CHARLOTTESVILLE CITY CODE <br />Distance between <br />Size or Equivalent Distance on Centers Bearing's <br />2" x 12" 12" 20' 0" <br />16" 18' 0" <br />3" x 12" 12" 23' 0" <br />16" 21' 0" <br />2" x 14" 12" 23' 8" <br />16" 21' 6" <br />2/" x 14" 12" 25' 6" <br />16" 23' 0" <br />3" x 14" 12" 27' 0" <br />16" 24' 6" <br />Note: The construction of floors in all other buildings shall be <br />designed to carry the live loads as given in the following sub- <br />section: <br />I. Minimum live loads required. <br />In all buildings hereafter erected, altered or repaired (where <br />such alterations or repair, in the judgment of the building shall <br />require new floor construction), all floor construction shall be <br />constructed in accordance with the following table of minimum <br />live load requirements: <br />Hotels (upper floors), apartment houses, dormitories, <br />hospitals ...................................... 60 lbs. <br />Schools ........................................... 75 lbs. <br />Office buildings (ground floor), corridors, stairs and lob- <br />bies in all buildings of public nature .............. 90 Ibs. <br />Assembly rooms, main floors of theatres, ball rooms, <br />gymnasiums, or any rooms to be used for drilling, <br />dancing, grandstands, ordinary stores for light <br />stock .........................................120 lbs. <br />Warehouses and light manufacturing .......... 150 to 300 lbs. <br />Special provision shall be made for heavy concentrated loads. <br />An addition of 509o' shall be made for floors carrying, moving or <br />travelling machinery. <br />Seo. 494(32). Light and ventilation. <br />(a) In all buildings every sleeping room shall be provided with <br />a window or windows opening directly upon a street, yard, or <br />court, which windows or openings shall equal in area to at least <br />one-tenth of the floor area of the room. <br />1 <br />1 <br />1 <br />1 <br />J <br />Distance between <br />Size or Equivalent <br />Distance on Centers <br />Bearings <br />2" x 8" <br />12" <br />14' 0" <br />16" <br />1�' 8- <br />3" x 8" <br />12" <br />16' Cr <br />16" <br />14' 6" <br />2" x 10" <br />12" <br />17' 6" <br />16" <br />15' 9" <br />3" x 10" <br />12" <br />19' 3" <br />16" <br />17' 6" <br />296 CHARLOTTESVILLE CITY CODE <br />Distance between <br />Size or Equivalent Distance on Centers Bearing's <br />2" x 12" 12" 20' 0" <br />16" 18' 0" <br />3" x 12" 12" 23' 0" <br />16" 21' 0" <br />2" x 14" 12" 23' 8" <br />16" 21' 6" <br />2/" x 14" 12" 25' 6" <br />16" 23' 0" <br />3" x 14" 12" 27' 0" <br />16" 24' 6" <br />Note: The construction of floors in all other buildings shall be <br />designed to carry the live loads as given in the following sub- <br />section: <br />I. Minimum live loads required. <br />In all buildings hereafter erected, altered or repaired (where <br />such alterations or repair, in the judgment of the building shall <br />require new floor construction), all floor construction shall be <br />constructed in accordance with the following table of minimum <br />live load requirements: <br />Hotels (upper floors), apartment houses, dormitories, <br />hospitals ...................................... 60 lbs. <br />Schools ........................................... 75 lbs. <br />Office buildings (ground floor), corridors, stairs and lob- <br />bies in all buildings of public nature .............. 90 Ibs. <br />Assembly rooms, main floors of theatres, ball rooms, <br />gymnasiums, or any rooms to be used for drilling, <br />dancing, grandstands, ordinary stores for light <br />stock .........................................120 lbs. <br />Warehouses and light manufacturing .......... 150 to 300 lbs. <br />Special provision shall be made for heavy concentrated loads. <br />An addition of 509o' shall be made for floors carrying, moving or <br />travelling machinery. <br />Seo. 494(32). Light and ventilation. <br />(a) In all buildings every sleeping room shall be provided with <br />a window or windows opening directly upon a street, yard, or <br />court, which windows or openings shall equal in area to at least <br />one-tenth of the floor area of the room. <br />1 <br />1 <br />1 <br />1 <br />J <br />