s <br />• <br />The portion of the stack above the offset shall be sized as <br />22.1-87. Table 2 -Fixtures Not Listed In Table 1 Shall Be <br />With Table 2. <br />for a regular stack based on the total number of fixtures above <br />Estimated in Accordance <br />the offset. <br />Fixture Drain or Trap Size Fixture Unit Value <br />The offset shall be sized as for a building drain. (Table 3, <br />11/z inches and smaller 1 <br />Col. 5.) <br />11. inches 2 <br />2 <br />The portion of the stack below the offset shall be sized as <br />2 inches 3 <br />21/2 inches 4 <br />for the offset or based on the total number of fixture units on <br />3 inches 5 <br />the entire stack, whichever is the larger. ( See Table 4, Col. 4.) <br />4 inches 6 <br />A relief vent for the offset shall be installed as provided in <br />Sec. 22.1-116 (b) (c) (d) and in no case shall the horizontal <br />22.1-88. Valves for Continuous Flow. <br />branch connect to the stack with 2 feet above or below the <br />For a continuous or semi -continuous flow into a drainage <br />offset.um <br />ejector, air conditioning <br />system, such as from a pump, pump e j <br />equipment or similar device, two fixture units shall be allowed <br />22.1-85. Fixture Units. <br />for each gallon -per -minute of flow. <br />Fixture unit values as given in Table 1 designate the relative <br />22.1-89. Determination of Sizes for the Drainage System. <br />load weight of different kinds of fixtures which shall be em- <br />ployed in estimating the total load carried by soil waste pipe <br />Maximum fixture unit load. The maximum number of fix - <br />and shall be used in connection with the tables of sizes for <br />ture units that may be connected to a given size of building <br />soil, waste, and rain pipe for which the permissible load is <br />sewer, building drain, horizontal branch, or vertical soil or <br />given in terms of fixture units. <br />waste stack is given in Tables 3 and 4. <br />22.1-90. Table 3 -Building Drains and Sewers. <br />Diameter Maximum Number of Fixture Units That May <br />of be Connected to Any Portion' of the Building <br />• <br />Pipe Drain or the Building Sewer <br />Fall Per Foot <br />1/16 Inch 1/8 Inch 1/t Inch 1/2 Inch <br />Inches <br />2 21 26 <br />21i, 24 31 <br />3 202 272 362 <br />4 180 216 250 <br />5 390 480 575 <br />6 700 840 1000 <br />8 1400 1600 1920 2300 <br />10 2500 2900 3500 4200 <br />12 3900 4600 5600 6700 <br />15 7000 8300 10000 12000 <br />1. Includes branches of the Building Drain. <br />2. No water closet shall be connected to a 3 inch horizontal drain greater <br />than 3 feet in length. <br />22.1-91. Table 4 -Horizontal Fixture Branches and Stacks. <br />22.1-86. Table 1 -Fixture Units Per Fixture or Group. <br />Maximum Number of Fixture Units That May Be Connected to: <br />Minimum Size 2 <br />Fixture -Unit Value of Trap <br />One Stack Of More Than 3 Stories In Height <br />Fixture Type As Load Factors In Inches <br />F <br />Any 3 Stories In Total for Total At One <br />Horizontal) Height of3 Stack Story of Branch <br />1 Bathroom group consisting Tank Water Closet <br />Inches Fixture Branch Intervals Interval <br />of water closet, lavatory, 6 <br />bathtub or shower stall Flush -Valve <br />11/4 1 2 2 1 <br />Water Closet 8 <br />11/2 3 4 8 2 <br />Bathtub 1 (with or without <br />over -head shower) 2 11�i <br />2 6 10 24 6 <br />Bidet 3 2 - <br />Combination sink -and -tray 3 Nominal 11/2 <br />21/2 12 20 42 9 <br />Combination sink -and -tray <br />11/2 <br />3 202 303 60" 16` <br />with food 3 <br />Disposal Unit ods lqr. -. 4 Separate1 <br />4 106 240 500 90 <br />Dental Unit or Cuspidor 1 traps i <br />5 360 540 1100 200 <br />Dental Lavatory 1 11/4 <br />6 620 960 1900 350 <br />Drinking Fountain 1/2 1 <br />Dishwasher 2 Domestic 1 2 11/2 <br />8 1400 2200 3600 600 <br />Floor Drains 3 1 it/2 <br />10 2500 3800 5600 1000 <br />Kitchen Sink, Domestic 2 <br />Kitchen Sink, Domestic, with 11/2 <br />12 3900 6000 8400 1500 <br />food waste grinder 3 <br />Lavatory 4 1 Small P.O. 11/4 <br />15 7000 <br />Lavatory 1 2 Large P.O. 11/2 <br />Lavatory, barber, beauty 11/2 <br />1. Does not include branches of the Building Drain. <br />parlor 2 <br />2. No Water Closet shall be connected to a 3 inch horizontal branch <br />Lavatory, surgeon's 2 11/z <br />more than 3 feet in length. <br />• <br />Laundry tray (1 or 2 com- 11/2 <br />3. Not over six water closets. <br />partments) <br />Shower stall, domestic 2 2 <br />Shower (group) per head 2 3 <br />22.1-92. Minimum Size of Soil and Waste Stack. <br />Sinks <br />Surgeon's 3 11/2 <br />No soil or waste stack shall be smaller than the largest <br />Flushing rim (with valve) 8 3 <br />Service (trap standard) 3 <br />horizontal branch connected thereto except that a 4 x 3 W. C. <br />p <br />Service (P trap) 2 i�/2 <br />connection shall not be considered as a reduction in pipe size. <br />Pot, scullery, etc. 2 4 <br />Urinal, pedestal, syphon jet, <br />3 <br />blowout 8 Nominal <br />11/2 <br />22.1-93. Minimum Size of Stack Vent or Vent Stack. <br />Urinal, wall lip 4 <br />1 <br />Urinal, stall, washout 4 2 <br />Urinal trough 2 (each 2 ft. <br />An structure on which a building drain is installed shall <br />Y <br />section) 2 11/2 <br />have at least one stack vent or vent stack carried full size <br />Wash sink 2 (circular or <br />through the roof not less than 3 inches in diameter. <br />multiple) each set of <br />faucets 2 Nominal 11/2 <br />- <br />Water closet, tank -operated 4 Nominal 3 <br />Water closet, valve -operated 8 3 <br />22.1-94. Future Fixtures. <br />Domestic washing machine 2 11/2 <br />1. A shower head over a bathtub does not increase the fixture value. <br />When provision is made for the future installation of fix - <br />2. For determining fixture unit values for fixtures not listed, refer to <br />tures, those provided for shall be considered in determining <br />paragraph: Values For Continuous Flow. <br />the required sizes of drain pipes. Construction to provide <br />3. Size of floor drain shall be determined by the area of surface water <br />for such future installation shall be terminated with a plugged <br />to be drained. <br />4. Lavatories with 11/4 or 11/2 inch trap have the same load value; larger <br />fitting or fittings at the stack so as to form no dead end. <br />P.O. plugs have greater flow rate. <br />0 <br />