all <br />SUCH AWNINGS SHALL BE ERECTED WITH A CLEAR SPACE OF NOT LESS THAN SEVEN (7) FEET ABOVE THE SIDEWALK <br />LEVEL, INCLUDING CURTAINS, FLAGS OR SIMILAR PROJECTIONS AND SHALL NOT EXTEND IN A VERTICAL PLANE WITHIN <br />TWO (2) FEET OF THE CURB LINE. THE MECHANISM FOR ACTIVATING MOVABLE AWNINGS SHALL BE SECURELY ATTACHED <br />TO THE BUILDING AND SHALL BE FREE OF ANY SHARP PROJECTIONS WHICH MAY BE DANGEROUS TO PEDESTRIANS. <br />SECTION 121.3. MARQUEES AND CANOPIES. <br />AN ORNAMENTAL ROOF LIKE STRUCTURE PROJECTING FROM THE WALL OF A BUILDING. <br />WHEN SUCH STRUCTURE PROJECTS BEYOND THE PROPERTY LINE THEY SHALL NOT EXCEED THREE (3) FEET IN HEIGHT <br />AND SHALL BE ERECTED WITH A CLEAR SPACE OF NOT LESS THAN NINE (9) FEET ABOVE THE ADJACENT SIDEWALK LEVEL <br />AND SHALL NOT EXTEND BEYOND A VERTICAL PLANE TWO (2) FEET INSIDE THE CURB LINE. <br />SECTION 121.4. OPENINGS IN SIDEWALKS. <br />NO OPENINGS IN SIDEWALKS FOR AREAWAYS, CELLAR ENTRANCES, COAL OR FUEL HOLES, SIDEWALK ELEVATORS OR <br />SIMILAR CONSTRUCTION SHALL HEREAFTER BE PERMITTED WITHOUT APPROVAL OF THE COUNCIL OF THE CITY OF CHARLOTTES- <br />VILLE. <br />NO PERMIT SHALL BE GRANTED FOR SUCH OPENINGS IF THE CONSTRUCTION, MAINTENANCE OR USE OF THE SAME WOULD <br />RESULT IN CREATING A NUISANCE OR MENACE TO PERSONS OR PROPERTY. <br />SECTION 121.41. PERMIT REQUIREMENTS. <br />A BUILDING PERMIT FOR THE CONSTRUCTION OR REPAIR OF ANY SIDEWALK OPENING, APPROVED BY COUNCIL, SHALL <br />NOT BE ISSUED UNTIL PLANS AND SPECIFICATIONS SHALL HAVE BEEN SUBMITTED TO AND APPROVED BY THE BUILDING <br />OFFICIAL. <br />SUCH PLANS SHALL SPECIFY THE DIMENSIONS, THE CHARACTER OF THE PROPOSED CONSTRUCTION, THE METHOD OF <br />DRAINAGE, AND PROTECTION OF SUCH OPENINGS. <br />SECTION 121.42. <br />ALL SIDEWALK OPENINGS SHALL BE CONSTRUCTED, MAINTAINED AND USED SO AS NOT TO INTERFERE WITH ANY <br />SEWER LINE, WATER OR GAS SERVICE, FIRE OR SPRINKLER HYDRANT, MANHOLE, CATCH BASIN, CONDUIT OR OTHER <br />PUBLIC UTILITY. <br />THE MAINTENANCE OR USE OF SUCH SIDEWALK OPENINGS SHALL NOT BE TAKEN TO REST ANY TITLE THERETO IN THE <br />OWNER OF THE ADJOINING LAND, OR TO ABRIDGE IN ANY MANNER THE RIGHTS OF THE CITY THEREIN. <br />SECTION 121.43. GENERAL CONSTRUCTION REQUIREMENTS. <br />NO SIDEWALK ELEVATOR OR CELLAR VAULT SHALL BE INSTALLED IN ANY SIDEWALK HAVING A WIDTH OF LESS THAN <br />FIVE (5) FEET. NO SUCH OPENING SHALL BE MORE THAN (4) FEET IN ANY DIMENSION NOR SHALL IT EXTEND ACROSS <br />MORE THAN TWO-THIRDS (2/3) OF THE WIDTH OF THE SIDEWALK. <br />SUCH OPENINGS SHALL BE COVERED WITH A HEAVY METAL COVER SET IN A SUBSTANTIAL FRAME AND FASTENED <br />THERETO BY METAL HINGES. SUCH COVER AND FRAME SHALL BE KEPT WELL SCORED, AND NO PART OF EITHER, OR OF <br />THE HINGES OR LOCK ATTACHED THERETO SHALL PROJECT ABOVE THE SURFACE OF THE SIDEWALK. <br />GRATE COVERED VENTILATING OPENINGS SHALL BE DESIGNED WITH SPACES BETWEEN THE BARS NOT TO EXCEED <br />ONE-HALF (1/2) INCH AND SHALL BE OF SUCH CONSTRUCTION AS MAY BE APPROVED BY THE BUILDING OFFICIAL FOR <br />SUCH INSTALLATION. <br />COAL AND FUEL MANHOLES MAY BE INSTALLED IN ANY SIDEWALK; SHALL BE SUBSTANTIALLY FIXED IN THE SIDEWALK; <br />SHALL BE SCORED TO PREVENT SLIPPING; AND SHALL NOT EXCEED TWENTY-FOUR (24) INCHES IN ANY DIMENSION. <br />SECTION 121.44. EXISTING OPENINGS. <br />PERMISSION IS HEREBY GRANTED FOR THE MAINTENANCE AND USE OF ALL EXISTING SIDEWALK OPENINGS, CONSTRUCTED <br />OR MAINTAINED PRIOR TO .,JUNE 71 1954, PROVIDED THAT THE MAINTENANCE AND USE THEREOF SHALL BE SUBJECT TO ALL <br />THE PROVISIONS OF THIS CODE RELATING TO SUCH OPENINGS, AND UPON FAILURE OR REFUSAL OF THE OWNER OF SUCH <br />OPENING TO COMPLY WITH THIS SECTION, THE BUILDING OFFICIAL SHALL ORDER SUCH OPENING CLOSED AND SIDEWALK <br />PLACED IN ITS' ORIGINAL CONDITION. <br />LERK <br />ADOPTED BY THE COUNCIL <br />FEBRUARY 17, 1958 <br />AYES: MR. COLEMAN, MR. DAVIS, MR. MICHIE <br />AND MR. SCRIBNER. <br />NOES: NONE. (MR. WEINBERG ABSENT AT TIME) <br />PRESIDENT <br />