Laserfiche WebLink
ADOPTED BY THE COUNCIL APRIL 20, 1959 <br /> AYES: MR. COLEMAN, MR. DAVIS, MR. MICHIE, MR. SCRIBNER AND MR. WEINBERG. <br /> NOES: NONE. <br /> <br /> CLERK SIGNATURE <br /> PRESIDENT SIGNATURE <br /> <br /> AN ORDINANCE AMENDING AND REENACTING SECTION 23 OF CHAPTER 21 OF THE CHARLOTTESVILLE <br /> <br /> CITY CODE OF 1945 RELATING TO PLUMBING, DRAINAGE AND VENTILATION OF BUILDING. <br /> <br /> <br /> BE IT ORDAINED BY THE COUNCIL OF THE CITY OF CHARLOTTESVILLE THAT SECTION 23 OF CHAPTER 21 OF <br /> <br /> THE CHARLOTTESVILLE CITY CODE BE AND THE SAME IS HEREBY AMENDED AND REENACTED TO READ AS FOLLOWS: <br /> <br /> SECTION 23. PLUMBING, DRAINAGE AND VENTILATION OF BUILDING. <br /> <br /> <br /> (A) THE PLUMBING, DRAINAGE AND VENTILATION IN EVERY BUILDING SHALL BE SEPARATE AND <br /> <br /> INDEPENDENT OF THAT OR ANY OTHER LOT OR BUILDING, AND SHALL BE SEPARATELY AND INDEPENDENTLY <br /> <br /> CONNECTED WITH THE PUBLIC SEWER IN THE STREET OR ALLEY; AND IN A ROW OF TENEMENTS, EACH TENEMENT <br /> <br /> SHALL BE DEEMED A SEPARATE BUILDING; PROVIDED THAT NO CLOSET OR TOILET DESIGNED OR INTENDED FOR <br /> <br /> THE USE OF ANY PREMISES SHALL BE CONSTRUCTED OR MAINTAINED OUTSIDE OF THE BUILDING. EACH FLAT, <br /> <br /> APARTMENT HOUSE, FACTORY, CHURCH, THEATRE, SHALL BE CONSTRUED AS ONE BUILDING; PROVIDED, THAT <br /> <br />WHERE A FIRE WALL IN ANY BUILDING DIVIDED THE SAID BUILDING, THEN EACH PART SO DIVIDED, ALTHOUGH <br /> <br /> THERE BE BUT ONE ENTRANCE, SHALL HAVE SEPARATE AND INDEPENDENT PLUMBING, AND THERE SHALL BE <br /> <br /> INSTALLED IN EACH BUILDING A SANITARY CLOSET AND SINK FOR THE USE OF EACH FAMILY; PROVIDED, FURTHER <br /> <br /> THAT PRIVATE STABLES AND GARAGES MAY BE CONNECTED WITH THE BUILDING DRAIN, AND IF THOSE OR OTHER <br /> <br /> OUTSIDE FIXTURES ARE CONNECTED INTO A CAST IRON DRAIN RUNNING UNDER BUILDING, THE CAST IRON PIPE MUST <br /> <br /> BE EXTENDED NOT LESS THAN FIVE FEET FROM THE BUILDING BEFORE GLAZED VITRIFIED CLAY PIPE CAN BE USED. <br /> <br /> <br /> (B) THAT PART OF THE BUILDING AND FIXTURE DRAINS INSIDE THE WALLS AND UNDERNEATH THE BUILDING AND <br /> <br /> FIVE FEET OUTSIDE THE AREA OF FOUNDATION WALLS SHALL BE CONSTRUCTED OF WHAT IS KNOWN AS VICTORY <br /> <br /> WEIGHT OR HEAVIER CAST IRON SOIL PIPE AND OF THE FOLLOWING WEIGHTS: <br /> <br /> 2 INCH — 4 POUNDS PER FOOT <br /> 3 INCH — 6 POUNDS PER FOOT <br /> 4 INCH — 8 POUNDS PER FOOT <br /> 5 INCH — 11 POUNDS PER FOOT <br /> 6 INCH — 13 POUNDS PER FOOT <br /> 8 INCH — 20 POUNDS PER FOOT <br /> 10 INCH — 29 POUNDS PER FOOT <br /> 12 INCH — 38 POUNDS PER FOOT <br /> <br /> (C) ALL CAST IRON PIPE AND FITTINGS ARE TO BE COATED INSIDE AND OUT, UNLESS BY PERMISSION OF <br /> <br /> THE INSPECTOR OF PLUMBING TO USE UNCOATED PIPE. FITTINGS MAY BE STANDARD OR MEDIUM WEIGHT. <br /> <br /> <br /> (D) GLAZED VITRIFIED CLAY PIPE MAY BE USED FOR SEPARATE DRAINS RECEIVING THE WASTE FROM FIXTURES <br /> <br /> DISCHARGING ACID OR CORROSIVE WASTE WHEN INSTALLED BELOW THE GROUND LEVEL OR BELOW THE SURFACE <br /> <br /> OF BASEMENT FLOORS. THESE DRAINS SHALL BE EXTENDED TO THE BUILDING SEWER AND TRAPPED AT THEIR EXIT <br /> <br />FROM BUILDING, AND ALL JOINTS SHALL BE WELL PACKED WITH OAKUM AND POURED WITH AN APPROVED PIPE JOINT <br /> <br />COMPOUND. NO INTERCEPTING TRAP WILL BE PERMITTED IN A MAIN BUILDING SEWER OR DRAIN. <br /> <br /> <br /> (E) NO PRIVY OR CESSPOOL SHALL BE CONNECTED WITH THE BUILDING SEWER OR DRAIN. ALL DRAINS SHALL <br /> <br /> BE RUN AS STRAIGHT AS PRACTICABLE. CHANGES IN DIRECTION SHALL BE MADE WITH "Y" BRANCHES AND <br /> <br />ONE-EIGHTH OR ONE-SIXTH BENDS OR LONG SWEEP BENDS. SANITARY TEES OR SHORT ONE-QUARTER BENDS <br /> <br /> CAN BE USED WHEN SET UPRIGHT TO RECEIVE VENT OUTLET AND ALSO IN SOIL STACKS TO RECEIVE CLOSETS AND <br /> <br /> OTHER FIXTURE CONNECTIONS. <br /> <br /> <br /> (F) ALL FLOOR AND AREA DRAINS MUST BE TRAPPED WITH CAST IRON TRAP SET NOT MORE THAN TWO FEET <br /> <br /> BELOW SURFACE. A CAST IRON STRAINER MUST BE CAULKED INTO AN INLET OF TRAP. FREE AREA OF STRAINER <br /> <br /> MUST BE EQUAL AREA OF SOIL PIPE TO WHICH IT CONNECTS. <br /> <br /> <br /> (G) ALL FLOOR DRAINS IN FLOORS ABOVE BASEMENT SHALL BE VENTED AS REQUIRED FOR OTHER FIXTURES; <br /> <br />PROVIDED, THAT IF A SEPARATE STACK IS RUN FROM THE MAIN BUILDING DRAIN AND EXTENDED THROUGH ROOF, <br /> <br />STACK VENTING WILL BE SUFFICIENT IF BRANCHES TO STACK DO NOT EXCEED 20 FEET IN LENGTH. <br /> <br />