• <br />CLERK <br />ADOPTED BY THE COUNCIL <br />APRIL 20, 1959 <br />AYES: MR. COLEMAN, MR. DAVIS, MR. MICHIE, <br />MR. SCRIBNER AND MR. WEINBERG. <br />NOES: NONE. <br />ESIDENT <br />AN ORDINANCE AMENDING AND REENACTING SECTION 23 OF CHAPTER 21 OF <br />THE CHARLOTTESVILLE CITY CODE OF 1945 RELATING TO PLUMBING, DRAINAGE <br />AND VENTILATION OF BUILDING. <br />BE IT ORDAINED BY THE COUNCIL OF THE CITY OF CHARLOTTESVILLE THAT SECTION 23 OF CHAPTER 21 OF THE <br />CHARLOTTESVILLE CITY CODE BE AND THE SAME IS HEREBY AMENDED AND REENACTED TO READ AS FOLLOWS: <br />SECTION 23. PLUMBING, DRAINAGE AND VENTILATION OF BUILDING. <br />(A) THE PLUMBING, DRAINAGE AND VENTILATION IN EVERY BUILDING SHALL BE SEPARATE AND INDEPENDENT <br />OF THAT OR ANY OTHER LOT OR BUILDING, AND SHALL BE SEPARATELY AND INDEPENDENTLY CONNECTED WITH THE <br />• <br />PUBLIC SEWER IN THE STREET OR ALLEY; AND IN <br />A <br />ROW OF TENEMENTS, EACH TENEMENT SHALL BE DEEMED A <br />SEPARATE BUILDING; PROVIDED THAT NO CLOSET <br />OR <br />TOILET DESIGNED OR INTENDED FOR THE USE OF ANY PREMISES <br />SHALL BE CONSTRUCTED OR MAINTAINED OUTSIDE <br />OF <br />THE BUILDING. EACH FLAT, APARTMENT HOUSE, FACTORY, <br />CHURCH, THEATRE, SHALL BE CONSTRUED AS ONE BUILDING; PROVIDED, THAT WHERE A FIRE WALL IN ANY BUILDING <br />DEVIDED THE SAID BUILDING, THEN EACH PART SO DEVIDED, ALTHOUGH THERE BE BUT ONE ENTRANCE, SHALL HAVE <br /><'V SEPARATE AND INDEPENDENT PLUMBING, AND THERE SHALL BE INSTALLED IN EACH BUILDING A SANITARY CLOSET <br />W <br />AND SINK FOR THE USE OF EACH FAMILY; PROVIDED, FURTHER THAT PRIVATE STABLES AND GARAGES MAY BE <br />CONNECTED WITH THE BUILDING DRAIN, AND IF THOSE OR OTHER OUTSIDE FIXTURES ARE CONNECTED INTO A CAST <br />IRON DRAIN RUNNING UNDER BUILDING, THE CAST IRON PIPE MUST BE EXTENDED NOT LESS THAN FIVE FEET FROM <br />THE BUILDING BEFORE GLAZED VITRIFIED CLAY PIPE CAN BE USED. <br />(B) THAT PART OF THE BUILDING AND FIXTURE DRAINS INSIDE THE WALLS AND UNDERNEATH THE BUILDING <br />AND FIVE FEET OUTSIDE THE AREA OF FOUNDATION WALLS SHALL BE CONSTRUCTED OF WHAT IS KNOWN AS VICTORY <br />WEIGHT OR HEAVIER CAST IRON SOIL PIPE AND OF THE FOLLOWING WEIGHTS: <br />FIXTURE CONNECTIONS. <br />(F) ALL FLOOR AND AREA DRAINS MUST BE TRAPPED WITH CAST IRON TRAP SET NOT MORE THAN TWO FEET <br />BELOW SURFACE. A CAST IRON STRAINER MUST BE CAULKED INTO AN INLET OF TRAP. FREE AREA OF STRAINER <br />MUST BE EQUAL AREA OF SOIL PIPE TO WHICH IT CONNECTS. <br />• (G) ALL FLOOR DRAINS IN FLOORS ABOVE BASEMENT SHALL BE VENTED AS REQUIRED FOR OTHER FIXTURES; <br />PROVIDED, THAT IF A SEPARATE STACK IS RUN FROM THE MAIN BUILDING DRAIN AND EXTENDED THROUGH ROOF, <br />STACK VENTING WILL BE SUFFICIENT IF BRANCHES TO STACK DO NOT EXCEED 20 FEET IN LENGTH. <br />2 INCH <br />4 POUNDS <br />PER FOOT <br />3 INCH <br />6 POUNDS <br />PER FOOT <br />4 INCH <br />8 POUNDS <br />PER FOOT <br />5 INCH <br />11 POUNDS <br />PER FOOT <br />6 INCH <br />13 POUNDS <br />PER FOOT <br />8 INCH <br />20 POUNDS <br />PER FOOT <br />10 INCH <br />29 POUNDS <br />PER FOOT <br />12 INCH <br />38 POUNDS <br />PER FOOT <br />(C) ALL CAST IRON PIPE <br />AND FITTINGS ARE TO BE <br />COATED INSIDE AND OUT, UNLESS BY PERMISSION OF <br />THE INSPECTOR OF PLUMBING TO <br />USE UNCOATED PIPE. FITTINGS <br />MAY BE STANDARD OR MEDIUM WEIGHT. <br />(D) GLAZED VITRIFIED CLAY <br />PIPE MAY BE USED FOR <br />SEPARATE DRAINS RECEIVING THE WASTE FROM <br />• <br />FIXTURES DISCHARGING ACID OR <br />CORROSIVE WASTE WHEN <br />INSTALLED BELOW THE GROUND LEVEL OR BELOW THE <br />SURFACE OF BASEMENT FLOORS. <br />THESE DRAINS SHALL BE <br />EXTENDED TO THE BUILDING SEWER AND TRAPPED AT <br />THEIR EXIT FROM BUILDING, AND <br />ALL JOINTS SHALL BE <br />WELLPACKED WITH OAKUM AND POURED WITH AN APPROVED <br />PIPE JOINT COMPOUND. NO INTERCEPTING <br />TRAP WILL BE <br />PERMITTED IN A MAIN BUILDING SEWER OR DRAIN. <br />(E) NO PRIVY OR CESSPOOL <br />SHALL BE CONNECTED <br />WITH THE BUILDING SEWER OR DRAIN. ALL DRAINS <br />SHALL BE RUN AS STRAIGHT AS <br />PRACTICABLE. CHANGES <br />IN DIRECTION SHALL BE MADE WITH "Y" BRANCHES AND <br />ONE-EIGHTH OR ONE-SIXTH BENDS <br />OR LONG SWEEP BENDS. <br />SANITARY TEES OR SHORT ONE-QUARTER BENDS CAN BE <br />USED WHEN SET UPRIGHT TO RECEIVE <br />VENT OUTLET AND ALSO IN SOIL STACKS TO RECEIVE CLOSETS AND OTHER <br />FIXTURE CONNECTIONS. <br />(F) ALL FLOOR AND AREA DRAINS MUST BE TRAPPED WITH CAST IRON TRAP SET NOT MORE THAN TWO FEET <br />BELOW SURFACE. A CAST IRON STRAINER MUST BE CAULKED INTO AN INLET OF TRAP. FREE AREA OF STRAINER <br />MUST BE EQUAL AREA OF SOIL PIPE TO WHICH IT CONNECTS. <br />• (G) ALL FLOOR DRAINS IN FLOORS ABOVE BASEMENT SHALL BE VENTED AS REQUIRED FOR OTHER FIXTURES; <br />PROVIDED, THAT IF A SEPARATE STACK IS RUN FROM THE MAIN BUILDING DRAIN AND EXTENDED THROUGH ROOF, <br />STACK VENTING WILL BE SUFFICIENT IF BRANCHES TO STACK DO NOT EXCEED 20 FEET IN LENGTH. <br />