BE SECURELY FASTENED TO THE TOP RING WITH JOINTS OF EQUAL TIGHTNESS TO THOSE BETWEEN THE RINGS. TANKS <br />SHALL BE COVERED WITH ASPHALTUM OR OTHER NONRUSTING PAINT OR COATING. ALL PIPE CONNECTIONS SHALL BE <br />MADE THROUGH FLANGES OR REINFORCED METAL SECURELY RIVETED, WELDED OR BOLTED TO THE TANK AND MADE THOROUGH- <br />LY TIGHT. THE USE OF WOODEN -TOP TANKS IS PROHIBITED. <br />TANKS SHALL BE CONSTRUCTED ENTIRELY OF METALI INCLUDING THE TOP., SIDES AND BOTTOM. ALL OPENINGS <br />SHALL BE GASTIGHT EXCEPT BENEATH THE VENT, WHICH SHALL BE SCREENED. ALL TANKS SHALL BE ELECTRICALLY <br />GROUNDED BY RESTING DIRECTLY ON MOIST EARTH OR OTHERWISE ELECTRICALLY GROUNDED TO PERMANENT MOISTURE, <br />PREFERABLY TO WATER PIPING, AND TO THE SATISFACTION OF THE CITY ELECTRICIAN AND THE CHIEF OF THE FIRE <br />DEPARTMENT. IVO INSULATED CONNECTION SHALL BE PERMITTED. TELEPHONE OR SIMILAR POLES OR OTHER PROJECTIONS <br />LIABLE TO ACT AS DISCHARGE POINTS SHALL BE KEPT AS FAR AS PRACTICABLE FROM TANKS. <br />IF BURIED UNDERGROUND, THE TANKS SHALL BE LOWER THAN THE FLOORS, BASEMENTS, CELLARS OR PITS OF ALL <br />BUILDINGS WITHIN A RADIUS OF FIFTY FEET. THE TOP OF THE TANK SHALL ALSO BE AT LEAST THREE FEET UNDER <br />THE GROUND AND BELOW ANY PIPING TO WHICH THE TANK MAY BE CONNECTED. EXCEPT IN LIEU OF THE THREE FEET OF <br />EARTH, TANKS MAY BE BURIED UNDER EIGHTEEN INCHES OF EARTH AND COVERED WITH REINFORCED CONCRETE., AS LEAST <br />SIX INCHES IN THICKNESS; WHICH SHALL EXTEND AT LEAST ONE FOOT BEYOND THE OUTLINE OF THE TANK IN ALL <br />DIRECTIONS, SHALL BE SET ON A FIRM FOUNDATION AND SHALL BE SURROUNDED WITH SOFT EARTH OR SAND, WELL TAMPED <br />INTO PLACE, OR ENCASED IN CONCRETE. THE TANK MAY HAVE A TEST WELL; IF THE TEST WELL EXTENDS NEAR THE <br />BOTTOM OF THE TANK AND TWELVE FEET ABOVE THE SOURCE OF SUPPLY., AND THE TOP SHALL BE HERMETICALLY SEALED <br />AND LOCKED EXCEPT WHEN NECESSARILY OPEN. THE TANK SHALL HAVE A VENT PIPE AT LEAST ONE INCH IN DIAMETER <br />WHICH SHALL EXTEND FROM THE TOP OF THE TANK TO AT LEAST TWELVE FEET ABOVEGROUND LEVEL AND SHALL TERMINATE <br />IN A GOOSE NECK PROTECTED IN THE OUTER END BY A 40 X 40 MESH OR EQUIVALENT NONCORRODIBLE WIRE SCREEN. <br />IF ERECTED ABOVEGROUND, THE TANK SHALL CONFORM TO THE SAME SPECIFICATIONS AND REQUIREMENTS AS HERETO- <br />FORE OUTLINED AND, IN ADDITIONY SUCH TANK SHALL BE ERECTED ONLY ON STEEL OR METAL SUPPORTS OF SUFFICIENT <br />SIZE AND THICKNESS FOR CARRYING THE LOAD TO BE IMPOSED THEREON AND ON A CONCRETE FOUNDATION. <br />ALL ABOVEGROUND TANKS SHALL BE INDIVIDUALLY DIKED OR THE ENTIRE PROPERTY, TOGETHER WITH CONTIGUOUS <br />OR ADJOINING PROPERTY USED FOR SUCH STORAGE OR PIPING SHALL BE PROVIDED WITH A DIKE OR RETAINING WALL <br />SUFFICIENT TO PREVENT THE DISCHARGE OF FLAMMABLE LIQUIDS ONTO OTHER PROPERTY IN CASE OF A RUPTURE IN THE <br />TANKS OR PIPING. <br />SUCH DIKES OR WALLS SHALL BE OF EARTH OR MASONRY CONSTRUCTION. THE IMPOUNDING BASIN SHALL HAVE A <br />CAPACITY AS SET FORTH IN SECTION 114.94 OF THE CHARLOTTESVILLE BUILDING CODE. THE HEIGHT AND CAPACITY <br />OF THE DIKES SHALL BE PROPERLY MAINTAINED TO AFFORD THE APPROVED PROTECTION. EARTHEN DIKES SHALL HAVE A <br />FLAT SECTION AT THE TOP AND SHALL HAVE A SLOPE CONSISTENT WITH THE ANGLE OF REPOSE OF THE MATERIALS OF <br />WHICH THEY ARE CONSTRUCTED. <br />ALL INSTALLATIONS UNDER THE AUTHORITY OF THIS ARTICLE SHALL BE UNDER THE DIRECTION AND MEET WITH THE <br />APPROVAL OF THE CITY MANAGER AND ALL SUCH INSTALLATIONS SHALL BE MADE IN WORKMANLIKE MANNER AND •IN <br />ACCORDANCE WITH RECOGNIZED STANDARDS CONSISTENT WITH SAFETY AND GOOD ENGINEERING. EXCEPT WHEN HEREIN <br />OTHERWISE PROVIDED, THE APPLICABLE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS SHALL BE RECOGNIZED. <br />ADOPTED BY THE COUNCIL <br />.JUNE 51 1961 <br />AYES: MR. LEEP MR. MICHIE) MR. MOUNT AND <br />MR. SCRIBNER. <br />NOES: NONE. (MR. HAGGERTY ABSENT) <br />CLERK" PRESIDENT <br />