Laserfiche WebLink
AN ORDINANCE AMENDING AND RE-ENACTING <br /> <br />THE CODE OF THE CITY OF CHARLOTTESVILLE, <br /> <br />1959, BY THE REPEAL OF CHAPTER 22 AND BY <br /> <br />THE ADDITION THERETO OF A NEW CHAPTER <br /> <br />NUMBERED 22.1 ENTITLED “PLUMBING, SEWERS <br /> <br />AND SEWAGE DISPOSAL.” <br /> <br /> <br />BE IT ORDAINED by the Council of the City of Charlottesville that Chapter 22 of the Code of the City of Charlottesville, 1959, <br /> <br /> is hereby repealed and Chapter 22.1 is added to said Code and reads as follows: <br /> <br /> <br />CHAPTER 22. REPEALED. <br /> <br />CHAPTER 22.1. PLUMBING, SEWERS AND SEWAGE DISPOSAL. <br /> <br /> CHAPTER 22.1 <br /> <br /> PLUMBING, SEWERS AND SEWAGE DISPOSAL <br /> <br />ARTICLE I — ADMINISTRATION <br /> <br /> <br /> Sec. 22.1-1. Basic Principles <br /> <br />The basic principles of this Code are enunciated as basic goals in environmental sanitation worthy of accomplishment through <br /> <br /> properly designed, acceptably installed, and adequately maintained plumbing systems. <br /> <br />Some of the details of plumbing construction must vary, but the basic sanitary and safety principles are the same. The results <br /> <br /> desired and necessary to protect the health of the people are the same everywhere. <br /> <br />While the following principles are not Code requirements, when unforeseen situations arise which are not covered in the body of <br /> <br /> the Code, such principles shall be used to determine the intent of this Code. <br /> <br /> <br /> Principle No. 1 — Safe Water Supply <br /> <br />All premises intended for human habitation, occupancy, or use shall be provided with a supply of pure and wholesome water, <br /> <br />neither connected with unsafe water supplies nor subject to the hazards of backflow or back-siphonage. <br /> <br /> <br /> Principle No. 2 — Adequate Volume and Pressure <br /> <br />Plumbing fixtures, devices, and appurtenances shall be supplied with water in sufficient volume and at pressures adequate <br /> <br /> to enable them to function satisfactorily and without undue noise under all normal conditions of use. <br /> <br /> <br /> Principle No. 3 — Water Conservation <br /> <br />Plumbing shall be designed and adjusted to use the minimum quantity of water consistent with proper performance and cleaning. <br /> <br /> <br /> Principle No. 4 — Water Heating Safety <br /> <br />Devices for heating and storing water shall be so designed and so installed as to prevent dangers from explosion through overheating. <br /> <br /> <br />Principle No. 5 — Sewer Connection Required <br /> <br />Every building having plumbing fixtures installed and intended for human habitation, occupancy, or use on premises abutting <br /> <br />on a street, alley, or easement in which there is a public sewer shall have a connection with the sewer. <br /> <br /> <br />Principle No. 6 — Minimum Sanitary Fixtures <br /> <br />Each family dwelling unit on premises abutting on a sewer or with a private sewage disposal system shall be provided with <br /> <br />sanitary plumbing facilities adequate to meet the basic requirements of sanitation and personal hygiene, including a lavatory <br /> <br /> and bathtub or shower. <br /> <br /> <br />Principle No. 7 — Fixture Materials and Location <br /> <br />Plumbing fixtures shall be made of smooth, nonabsorbent material, shall be free from concealed fouling surfaces, and shall <br /> <br /> be located in ventilated enclosures. <br /> <br /> <br />Principle No. 8 — Drainage System Design <br /> <br />The drainage system shall be designed, constructed, and maintained so as to guard against fouling, deposit of solids and <br /> <br /> clogging, and with adequate cleanouts so arranged that the pipes may be readily cleaned. <br /> <br /> <br />Principle No. 9 — Durable Piping <br /> <br />The piping of the plumbing system shall be of durable material, free from defective workmanship, and so designed and <br /> <br />constructed as to give satisfactory service for its reasonable expected life. <br /> <br /> <br />Principle No. 10 — Water-Seal Traps <br /> <br />Each fixture directly connected to the drainage system shall be equipped with a water-seal trap. <br /> <br /> <br />Principle No. 11 — Ventilation of Drainage System <br /> <br />The drainage system shall be designed to provide an adequate circulation of air in all pipes, with no danger of siphonage, <br /> <br />aspiration, or forcing of trap seals under conditions of ordinary use. <br /> <br /> <br />Principle No. 12 — Vent Terminals <br /> <br />Each vent terminal shall extend to the outer air and be so installed as to minimize the possibilities of clogging and the return <br /> <br /> of foul air to the building. <br /> <br /> <br />Principle No. 13 — Testing for Leaks and Defects <br /> <br />The plumbing system shall be subjected to such tests as will effectively disclose all leaks and defects in the work. <br /> <br /> <br />Principle No. 14 — Harmful Substances Prohibited <br /> <br />No substance which will clog the pipes, produce explosive mixtures, destroy the pipes or their joints, or interfere unduly with <br /> <br /> the sewage disposal process shall be allowed to enter the building drainage system. <br /> <br /> <br />Principle No. 15 — Protection Against Contamination <br /> <br />Proper protection shall be provided to prevent contamination of food, water, sterile goods, and similar materials by backflow or sewage. <br /> <br />When necessary, the fixture, device, or appliance shall be connected indirectly with the building drainage system. <br /> <br /> <br /> Definitions of Terms <br /> <br /> <br />AIR GAP <br /> <br />An air gap in a water supply system is the unobstructed vertical distance through the free atmosphere between the lowest <br /> <br /> opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood-level rim of the receptacle. <br /> <br />ANCHORS - See SUPPORTS. <br /> <br /> APPROVED <br /> <br />Approved means accepted or acceptable under an applicable specification stated or cited in this Code, or accepted as <br /> <br /> suitable for the proposed use under procedures and powers by the Plumbing Board. <br /> <br /> AREA DRAIN <br /> <br />An area drain is a receptacle designed to collect surface or rain water from an open area. <br /> <br /> BACKFLOW <br /> <br />Backflow is the flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable supply of water <br /> <br />from any source or sources other than its intended source. (See BACK-SIPHONAGE.) <br /> <br />BACKFLOW CONNECTION <br /> <br />Backflow connection or condition is any arrangement whereby backflow can occur. <br /> <br />BACKFLOW PREVENTER <br /> <br />A backflow preventer is a device or means to prevent backflow into the potable water system. <br /> <br /> BACK-SIPHONAGE <br /> <br />Back-siphonage is the flowing back of used, contaminated, or polluted water from a plumbing fixture or vessel into a water <br /> <br /> supply pipe due to a negative pressure in such pipe. See BACKFLOW. <br /> <br /> BATTERY OF FIXTURES <br /> <br />A “battery of fixtures” is any group of two or more similar adjacent fixtures which discharge into a common horizontal waste or soil branch. <br /> <br /> BOILER BLOW-OFF <br /> <br />A boiler blow-off is an outlet on a boiler to permit emptying or discharge of sediment. <br /> <br /> BRANCH <br /> <br />A branch is any part of the piping system other than a main, riser or stack. <br /> <br /> BRANCH HORIZONTAL See HORIZONTAL BRANCH. <br /> <br /> BRANCH FIXTURE See FIXTURE BRANCH. <br /> <br />BRANCH INTERVAL <br /> <br />A branch interval is a length of soil or waste stack corresponding in general to a story height. <br /> <br />CROSS CONNECTION <br /> <br />A cross connection is a connection or arrangement between two piping systems whereby flow may occur from one system <br /> <br /> to the other, the direction of flow depending on the pressure differential between the two systems. <br /> <br />See BACKFLOW and BACK-SIPHONAGE. <br /> <br />DEAD END <br /> <br />A dead end is a branch leading from a soil, waste, or vent pipe, building drain, or building sewer, which is terminated at <br /> <br /> a developed distance of two feet or more by means of a plug or other closed fitting. <br /> <br />DEVELOPED LENGTH <br /> <br />The developed length of a pipe is the length along the center line of the pipe and fittings. <br /> <br />DIAMETER <br /> <br />Unless specifically stated, the term “diameter” is the nominal diameter as designated commercially. <br /> <br />DOUBLE OFFSET <br /> <br />A double offset is two changes of direction installed in succession or series in continuous pipe. <br /> <br />DOWNSPOUT See LEADER. <br /> <br />DRAIN <br /> <br />A drain is any pipe which carries waste water or water-borne wastes in a building drainage system. <br /> <br />DRAINAGE PIPING <br /> <br />See DRAINAGE SYSTEM. DRAINAGE SYSTEM <br /> <br />A drainage system, or drainage piping, includes all the piping within public or private premises which conveys sewage, <br /> <br />rain water, or other liquid wastes to a legal point of disposal, but does not include the mains of a public sewer system. <br /> <br />DUAL VENT See COMMON VENT. <br /> <br />DURHAM SYSTEM <br /> <br />Durham system is a term used to describe soil or waste systems where all piping is of threaded pipe, tubing, or other such <br /> <br /> rigid construction, using recessed drainage fittings to correspond to the types of piping. <br /> <br />EFFECTIVE OPENING <br /> <br />The effective opening is the minimum cross-sectional area at the point of water-supply discharge, measured or expressed in terms of: <br /> <br />1. the diameter of a circle; or <br /> <br />2. if the opening is not circular, the diameter of a circle of equivalent cross-sectional area. <br /> <br />(This is applicable to air gap.) <br /> <br />EXISTING WORK <br /> <br />Existing work is plumbing which has been installed or approved for installation prior to the effective date of this Code. <br /> <br />FIRM. See CONTRACTING FIRM. <br />