My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1924 ORDINANCES
Charlottesville
>
City Council
>
Ords Res App
>
BOOK 1_OCT 13 1904-APR 18 1932
>
1924 ORDINANCES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2025 4:09:01 PM
Creation date
9/18/2021 1:31:20 AM
Metadata
Fields
Template:
City Council
Doc Type
Other
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
other fixtures requiring vents, small bo either, lead, cast iron, galvanized wrought <br />iron or galvanized mild steel pipe with proper fittings. All pipes when not vertical <br />must have a continaou3 up grade to avoid trapping or condet1sation. <br />All water closets placed in buildings must be back vented by 2" pipes, be- <br />low the floor and as near the flange of closet as possible, except each as are here- <br />inafter specified. Where there is only one water closet on the line of soil pipe, <br />no back vent is required except main soil pipe running through roof, but when more <br />than one water closet is located in the line of soil pipe, all other except the top <br />closet shall be vented. No horizontal vent line longer than 3 ft. permitted beneath <br />floor. In all cases where closets are located more than 3 ft. from main vent `;hey <br />shall be vented and in cases of battery of closets the inspe,-;tor may authorize <br />the omission of the separate vents and th. substutition of an extension of a circuit <br />or continuous vent, not leas tilan 2" in diameter for two closets and 3" in diameter <br />IV for 3 to 6 closets. auch vents to be taken off at a point between the last two closets <br />not less than <br />or rising at an angle of/45 deg. from the last closet. <br />The vertical vent pipes for water closets in building more than four <br />stories in height, must be at least three inches in diamter with two incise branches <br />to each water closet bend or trap. `this pipe shall be connected near the base )f soil <br />pipe line and extended separately through the roof, with suitable branches from <br />eaoh floor connecting therewith. <br />All vent pipe terminals when within fifteen feet of window or other open- <br />ing, must be carried two feet above highest opening. <br />Back vents for fixtures shall be not less ti,an as follows: <br />1 -Lavatory ------------------------ 1._ 11 <br />2 -Lavatories --------- -------------11" <br />3 to 6 " -----------------------2" <br />1 sink ---------------------------- 11►, <br />2 <br />2 Sinks ---------------------------2" <br />3 to 6 sinks ----------------------2j" <br />1 BathTub ------------------------ 1-?►� <br />,2 to 6 bath tubs ------------------2" <br />1 Laundry 'iub 11 'trap)------- ---- 12►� <br />2 to 6 11 (1 'i'rap)---------- 2►� <br />1 Wall type urinal--------------- IP <br />2 to 6 wall type urinal---------- 2" <br />1 Urinal hall------------------- 2" <br />3 Urinal Sta11A------------------ 21' <br />3 to 6 Urinal Stall-------------- 3" <br />1 'Foot tub----------------------- li" <br />2 to 6 Foot tubs----------------- 21' <br />1 Slop Sink---------------------- 2" <br />3 Mop Sink------------ ------ 2" <br />3 to 6 Slop sinks---------------- 2�1' <br />Fixtures, other than ''.'ater clo:3ets, connecting into waste pipes, which do <br />not carry waste from closets located above them need not be back vented when tithin <br />three feet of such waste pipe; Thds section will apply only to main 4" soil Stack in <br />buildings up to 4 stories in height and the number of such fixtures shall not exceed <br />four. <br />Fixtures located m)re than 3 ft. from main or branch waste lines are to <br />be back vented except as specified elsewhere. <br />All openings left in soil, waste or vent pipes for any purpo6e and not <br />used in finishinJ shall be closed so as to be gas and water tight and in case of <br />vent pipe outlets where they are liable to hold water, they shall be connected to <br />waste, <br />
The URL can be used to link to this page
Your browser does not support the video tag.