382 <br />inches, or the finished grade of a lot if the building does not immed ately adjoin the side <br />exception buildings costing $2,000.00N or less. <br />Sec. 8. Incombustible walls, cornices, and roofs required wjthin limit$, <br />Every building hereafter erected or enlarged within the fire limits shall <br />be enclosed on all sides with wails constructed wholly of stone, well -burned brick, <br />concrete, or other equivalent incombustible materials; and shall have the roof, top, and <br />sides of all roof structures, including dormer windows, covered with incombustible <br />material. All cornices shall be of incombustible material except residences. <br />Sec. 9. Permissible wooden structures within fire limits. <br />(a) No frame or wooden structure shall hereafter be built within the <br />fire limits as given herein, or within the fire limits hereafger established, except the <br />following, and all roofs placed upon such buildings or structures shall have an incom. <br />bustible covering; <br />(b) Temporary one-story frame buildings for use of builders. No frame build. <br />ing shall be moved from without to within the fire limits. <br />(c) Bay windows when covered with incombustible material. <br />SEC. 10. 1.1-.epairing frame buildings within fire limits. <br />Any existing frame building within the fire limits, which may hereafter <br />be damaged by fire, decay, or otherwise to an amount greater than one-half of its <br />pre sent value, exclusive of the foundation, shall not be repaired or rebuilt, but shall <br />be removed. <br />Sec. 11. What buildings required to be fireproof. <br />(a) All buildings erected for the use of a public Garage, coffee roaster, <br />stable, bakery, or dry cleaning establishment within the fire limits Mall be of fire- <br />proof construction. <br />struotion. <br />(b) All buildings over 100 feet in height, shall be of fireproof con- <br />Sec. 12. Limits of height and area. <br />(a) Except as specified in Section 28, no building hereafter erected within <br />the corporate limits, having walls of hollow terra cotta or concrete blocks, shall <br />exceed three stories, or forty (40) feet in height, and no building hereafter erected <br />or altered shall exceed eight(6) stories or one hundred (100) feet in height, unleae <br />it be of (slow burning or) fireproof construction. <br />(b) The floor area between fire walls of non -fireproof buil4inge shall <br />not exceed the following; When fronting on one street, 5,000 square feet; When fronting <br />on two streets, 6,000 square feet, and when fronting on three streets 7,500 square feet' <br />These area limits may be increased under the following conditions as indicated: <br />For non -fireproof buildings, fully equipped with approved automatic <br />sprinklers, 66-2/3%. <br />For fireproof buildings, not exceeding 125 feet in height, 50%0 <br />For fireproof buildings not exceeding 126 feet in height, fully equipped <br />with approved automatic sprinklers, 10016. <br />Seo, 13. Walle. <br />(a) All exterior or division walls of buildings hereafter erected shall be <br />of sufficient thickness to support the lead to be oarried= but in no ease shall a brick, <br />stone, concrete, or hollow block wall be less than twelve (12) inches thick except panel <br />walls, non -load bearing and in dwelling house class,, <br />�J <br />